BRZHS - TOOLMARKER'S INK REMOVER 7001 160 025EY
- MSDS: BRZHS
- Manufacturer: CROWN INDUSTRIAL PRODUCTS CO INC
- Product Name: TOOLMARKER'S INK REMOVER 7001 160 025EY
- National Stock Number: 6850-00N040155
Product Identification
Product ID:TOOLMARKER'S INK REMOVER 7001 160 025EY
MSDS Date:12/22/1988
FSC:6850
NIIN:00N040155
MSDS Number: BRZHS
Responsible Party
HEBRON, IL 60034
US
Emergency Phone: 815-648-2424;815-338-2141
Info Phone: 815-648-2424
Preparer: ROBERT E. BAYTON
Cage: 92381
Contractor
Telephone: 815-648-2424
Cage: 92381
Ingredients
ETHANE,1,1,1-TRICHLORO-; (1,1,1-TRICHLOROETHANE)
CAS: 71-55-6
RTECS: KJ2975000
Fraction By Weight: 31-50%
OSHA PEL 350 PPM;450 PPM STEL
ACGIH TLV: 350 PPM;450 PPM STEL
EPA Report Quantity: 1000 LBS
DOT Report Quantity: 1000 LBS
2-BUTANONE; (METHYL ETHYL KETONE)
CAS: 78-93-3
RTECS: EL6475000
Fraction By Weight: 1-10%
OSHA PEL 200 PPM;300 PPM STEL
ACGIH TLV: 200 PPM;300 PPM STEL
EPA Report Quantity: 5000 LBS
DOT Report Quantity: 5000 LBS
ACETONE
CAS: 67-64-1
RTECS: AL3150000
Fraction By Weight: 11-30%
OSHA PEL 1000PPM
ACGIH TLV: 750PPM/1000STEL;9293
EPA Report Quantity: 5000 LBS
DOT Report Quantity: 5000 LBS
TOLUENE
CAS: 108-88-3
RTECS: XS5250000
Fraction By Weight: 1-10%
OSHA PEL 200 PPM/150 STEL
ACGIH TLV: 50 PPM; 9293
EPA Report Quantity: 1000 LBS
DOT Report Quantity: 1000 LBS
ISOPROPYL ALCOHOL
CAS: 67-63-0
RTECS: NT8050000
Fraction By Weight: 1-10%
OSHA PEL 400 PPM;500 PPM STEL
ACGIH TLV: 400 PPM;500 PPM STEL
LIQUIFIED PETROLEUM GAS, SWEETENED
CAS: 68475-86-8
Fraction By Weight: 11-30%
OSHA PEL 900 PPM (MFR)
ACGIH TLV: 900 PPM (MFR)
P-DIOXANE (DIETHYLENE DIOXIDE); 1,4-DIOXANE
CAS: 123-91-1
RTECS: JG8225000
Fraction By Weight: 0.9%
OSHA PEL S, 100 PPM
ACGIH TLV: S, 25 PPM; 9293
EPA Report Quantity: 100 LBS
DOT Report Quantity: 100 LBS
Hazards
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:YES IARC:YES OSHA:NO
Health Hazards Acute and Chronic:ACUTE: PRIMARILY A CNS DEPRESSANT.
INHAL: CAN CAUSE IRRIT TO RESP SYS, DIZZ, LT-HEAD, NAUS/HDCH.
INGEST: NOT LIKELY, LOW TOX. EYE: IF LIQ IS SPLASHED INTO EYES, CAN
CAUSE DISCOMFORT, PAIN & IRRIT. SKI N: PRLNGD & RPTD CONT CAN CAUSE
DEFAT OF SKIN, IRRIT &/OR DERM. SKIN ABSORP: NOT LIKELY IN TOX
AMTS. (EFTS OF OVEREXP)
Explanation of Carcinogenicity:1,4-DIOXANE: GROUP 2B IARC MONOGRAPH,
VOL 7, P201, 1987; ANTICIPATED TO BE CARCINOGEN, NTP 6TH ANNUAL
RPT, 1991. .
Effects of Overexposure:HLTH HAZ:CHLOROCARBON MATLS HAVE PRDCD SENSIT
OF MYOCARDIUM TO EPINEPHRINE IN LAB ANIMALS & COULD HAVE SIMILAR
EFT IN HUMANS. ADRENOMIMETICS (E.G., EPINEPHRINE) MAY BE
CONTRAINDICATED EXCEPT FOR LIFE- SUSTAINING USES IN HUMANS ACUTELY
OR CHRONICALLY EXPOSED TO CHLOROCARBONS . NOTE: TOLUENE CAS#
108-88-3(SUPP DATA)
Medical Cond Aggravated by Exposure:MAY INCREASE MYOCARDIAL
IRRITABILITY. AVOID EPINEPHRINE OR SIMILAR DRUGS IF AT ALL
POSSIBLE.
First Aid
First Aid:CALL A PHYSICIAN. EYES: FLUSH WITH WATER FOR AT LEAST 15
MINUTES OR UNTIL IRRITATION SUBSIDES. SKIN: REMOVE ALL CONTAMINATED
CLOTHING. WASH SKIN WITH SOAP AND WATER. INHAL: REMOVE FROM
EXPOSURE IMMED. IF BREATHING IS STOPPED OR IRREGULAR, BEGIN ARTF
RESP AND ADMINISTER OXYGEN. INGEST: DO NOT INDUCE VOMITING. DRINK
PLENTY OF WATER.
Fire Fighting
Flash Point Method:TCC
Flash Point:SUPP DATA
Lower Limits:1.8%
Upper Limits:9.5%
Extinguishing Media:CARBON DIOXIDE, DRY CHEMICAL, FOAM.
Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED PRESSURE DEMAND SCBA
AND FULL PROTECTIVE EQUIPMENT .
Unusual Fire/Explosion Hazard:TREAT AS CYLINDERS OF COMPRESSED GAS.
COOL CONTRS EXPOSED TO HEAT/FLAME-OVERHEATED CONTRS MAY EXPLODE.
THERMAL DECOMP PROD MAY INCL HCL & PHOSGENE .
Accidental Release
Spill Release Procedures:VENTILATE AREA. REMOVE ALL SOURCES OF
IGNITION. CLEAN UP WITH INERT MATERIALS AND DISPOSE OF IN
ACCORDANCE WITH ALL LOCAL, STATE AND FEDERAL REGULATIONS.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
Handling
Handling and Storage Precautions:DO NOT STORE IN DIRECT SUNLIGHT, NEAR
OPEN FLAMES/@ TEMP EXCEEDING 120F. DO NOT SMOKE WHILE SPRAYING. USE
ONLY AS DIRECTED.
Other Precautions:INTENTIONAL MISUSE BY DELIB CONC VAPS & INHALING
CONTENTS CAN BE HARMFUL/FATAL. NO SMOKING IN AREA OF USE. DO NOT
USE IN GEN VICIN OF ARC WELD, OPEN FLAMES/HOT SURF. HEAT &/OR UV
RADIA MAY CAUSE FORM OF HCL AND/OR PHOSGENE .
Exposure Controls
Respiratory Protection:RESPIRATORY PROTECTION PROGRAM SHOULD BE I/A/W
29CFR1910.134. USE NIOSH/MSHA APPROVED RESPIRATOR APPROPRIATE FOR
EXPOSURE OF CONCERN .
Ventilation:LOCAL EXHAUST IS ADEQUATE.
Protective Gloves:POLYETHYLENE OR NEOPRENE.
Eye Protection:ANSI APPRVD CHEM WORKERS GOGGLES .
Other Protective Equipment:PROTECTIVE CLOTHING AND EQUIPMENT: SEE 29
CFR 1910.133 & 132.
Work Hygienic Practices:WASH SKIN WITH SOAP AND WATER.
Supplemental Safety and Health
VAPOR PRESSURE: AEROSOL: 50-55 PSIG@70F. FLASH PT: AEROSOL CONTAINER:
<20F,<-7C. EFTS OF OVEREXP: APPEARS ON NAVY LIST OF OCCUPATIONAL
CHEMICAL REPRODUCTIVE HAZARDS. SEEK CONSULTATION FROM APPROPRIATE
HEALTH PROFESSIONALS CONCERNING LATESTHAZARD LIST INFORMATION AND
SAFE HANDLING AND EXPOSURE RECOMMENDATIONS .
Chemical Properties
Boiling Pt:B.P. Text:105F,41C
Vapor Pres:SUPP DATA
Vapor Density:>1
Spec Gravity:1.03
Evaporation Rate & Reference:<1(ETHYL ETHER=1)
Solubility in Water:PARTIAL
Appearance and Odor:CLEAR, COLORLESS
Percent Volatiles by Volume:100
Stability
Stability Indicator/Materials to Avoid:YES
AVOID CONTAMINATION WITH CAUSTIC SODA, CAUSTIC POTASH OR OXIDIZING
MATERIALS.
Stability Condition to Avoid:OPEN FLAMES, SPARKS, ELECTRICAL ARCS.
Hazardous Decomposition Products:HYDROGEN CHLORIDE AND POSSIBLY
PHOSGENE.
Disposal
Waste Disposal Methods:AEROSOL CONTAINER: DO NOT PUNCTURE OR
INCINERATE. EMPTY CONTAINERS MAY BE DISPOSED OF THROUGH NORMAL
CHANNELS. FULL OR PARTIALLY FILLED CONTAINERS ARE CONSIDERED
HAZARDOUS WASTE. DISPOSE OF I/A/W FEDE RAL, STATE AND LOCAL
REGULATIONS .
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.